![]() (I can't find what is installed in your 21G-what is the generator's power rating?)Ī Multiplus can sustain 120A to the batteries or ~1400W. NickinCO - the only downside is the generator likely has way more capability than the converter can use to charge the batteries. Will you be running the generator to charge the batteries through the 8955LIS?Īnother consideration is that both your solar charging system and your 8955LIS will both be contributing to the recharge effort at the same time. Running two in parallel would allow me to charge them at up to 100A correct? This way I would see a theoretical max of 95A of charging with solar plus the converter.I'm trying to understand your post a little more. Running two in parallel would allow me to charge them at up to 100A correct? This way I would see a theoretical max of 95A of charging with solar plus the converter.Įdit: The SOK batteries are rated at a max 50A charge. In reality I’m not sure how often I would run them below 50% to actually NEED to flip the breaker but as a good American more is better right? □Įdit: The SOK batteries are rated at a max 50A charge. ![]() In the western US I’m assuming 600w of solar will replace about 30-32A per hour in good sun. I will also have 600w solar to top off the battery’s if I’m not around to flip the breaker at the 4 hour mark. Has anyone done this? Thoughts? I tried searching 8955-LIS without results. ![]() At the 4 hour mark I would have to flip the breaker for the converter so it resets itself for another 1-4 hour bulk charge. Being a 55A charger if I ran my battery bank down to close to zero it would take a little over 7 hours to fully recharge. My understanding is the 8955LIS will charge in bulk at 14.6 (if needed) for 1-4 hours. I’m leaning towards no for now just because my unit has the Cumins generator but I need to spend some nights in it first. The unit is cheap ($230 vs $1300) until I decide if I really need a Victron multiplus. For now I’m going to swap the stock WFCO 8955PEC converter and board for the 8955LIS which has a switch to flip between lithium and FLA. I’m planning on ordering two SOK 206aH batteries for a total of 412aH. We take care of our customers, keep up with future trends and provide best-in-class quality and value.So I think I’ve narrowed down my electrical system choices. It also allows the company to focus its resources on developing leading-edge solutions for the RV industry. Vertically integrated with Arterra Distribution enables WFCO to provide quality control at every supply chain level while achieving cost reductions. Our family-owned company has been providing technologically advanced and innovative quality power products for more than 40 years. Depending upon the answer, technicians are guided to a solution or WFCO posts new Converter troubleshooting guides for technicians on its website WFCO Electronics' power product line-up includes converters, inverters, energy management, transfer switches, WAGO connectors, power centers, and lithium-ion products. The handy one-page charts for each of the five series layouts in the graphic form a sequence of yes-and-no questions for technicians to answer about the problem. WFCO posts new Converter troubleshooting guides for technicians on its website - WFCO Electronics News News WFCO Electronics now provides step-by-step, online troubleshooting guides for its different power centers and deck mount converters.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |